2.9 KiB
UAE: Grass_Morning after replacing Edge, 2026-09-15
Device: g-box-27d83450 (server device 66); model 11,
Villa_18_Jumeirah_Irrigation; component 75, Grass_Morning.
Confirmed findings
- Server layout projection contained all eight current irrigation components.
- Grass_Morning resolved to register 1943 on module 186, device 66. The detached device 38 was absent from the model's live device relation.
- MQTT reported the current board available, with no Modbus error. This alone did not establish that the client had loaded its behavior model.
- At 17:52:48 Gulf time the kernel reported a bad ext4 block-bitmap checksum
on
/dev/mmcblk0p8and remounted/userdataread-only. - The client data directory is under
/userdata/itscreen. Its cached model files remained at 12:49, referring to the previous model, while its onscreen log reported failures writingjournal2.json. - The filesystem had no ext4 journal, and its fstab check pass was zero.
Recovery performed
- Backed up client state and
/userdatacontents (excluding swap and lost+found), verified the archive, and copied it outside the Edge. - Stopped the client and log watchdog, verified no users of
/userdata, and unmounted it.e2fsck -pfcompleted with code 1 (errors corrected). - Ran the existing
stage_env/iomatex-userdata-preparemechanism while the filesystem was unmounted. It enabled the journal and set fstab pass to 2. - Mounted the filesystem and restarted the client and watchdog timer.
- Confirmed read-write mount, clean filesystem, journal enabled, and storage
health status
ok. Client logs then confirmed all eight current components downloaded, including Grass_Morning; model files updated at 18:38 Gulf time.
Edge backup: /var/backups/iomatex-grass-20260915/.
An off-device copy is retained on UAE in
/home/ansible/its_docker/edge-recovery-20260915/ (root-only).
All eight components were checked through their resolved API interface relations: Grass uses 1943, Entrance 1944, Left Wall 1945, Right Wall 1946; morning and evening pairs share their intended output. Every resolved output belongs to module 186 / device 66. No additional old-device output was present.
No register tags were deleted. Register aliases are shared metadata, whereas device-to-model membership determines the live binding; indiscriminately deleting aliases on a detached device can damage other configurations.
The exact cause of the original filesystem corruption is not established. The reported eMMC lifetime estimate is 0–10% with normal pre-EOL status; this does not rule out hardware or power-loss faults. Journaled storage and boot-time checks reduce exposure, but do not guarantee against recurrence.
Physical Push activation still requires a separate observed start/stop test; successful configuration loading and an enabled UI button are not proof that the relay has switched.