Iomatex_OS/docs/releases/console-3.1.2.md

1.9 KiB

Edge Console 3.1.2 — 2026-09-18

  • Added the five input/output relationship modes for N4D8C12 / IOMATEX ExBd-12/12-12 to Modbus → Configuration Write, with descriptions, actual readback, explicit whole-board scope and independent desired/actual values.
  • Added a separate N4D8C12 library profile with zero-based register 0x00FD; numeric responses are not treated as proof of board identity. ExBd Nano remains a separate profile.
  • Added an authenticated maintenance operation that pauses the running client, checks the previous value, writes and verifies the requested value, releases the port and restores the client even after operation errors. Manual Modbus sessions must first be released.
  • Reused the existing confirmation dialog, styling, localization and update delivery. Added Russian and Polish labels; other locales use the existing English fallback for new strings.
  • Hardware and API tests cover invalid family/value, missing confirmation, stale state, busy port, read/write/readback failures and recovery failures. Browser checks cover 360/768/1024/1440 widths, cancel, read, write, target freezing and failed verification.

Install through Health → Edge Console → Update 3.1.2. This updates stage_ui; it does not change the IT-Screen App binary or stage_itscreen revision. No installation on the user's live device is performed as part of publication.

  • Remote access diagnostics now distinguish the local autossh connection from the registration server receiver and public Web Gateway. A connected SSH tunnel is shown as degraded when browser access is unavailable or unverified; the Console never reports receiver-only health as end-to-end readiness.
  • Switching registration environments clears the old tunnel target and stops its units before enrolling with the new server. If enrollment fails, enabled units cannot reconnect to the previous environment after reboot. Re-registering on the same server keeps the current tunnels until replacement succeeds.