Physical Android bench

Paired hardware is the same RK3566 tablet used by FaceAPI. Actual firmware is Android 13 (API 33), model RK3566, product rk3566_t, platform rk356x, ABI arm64-v8a. Android 11 (API 30) is the build minimum and was not available for a separate physical run. There is approximately 1.9 GiB usable RAM and 5.0 GiB free on /data at diagnosis. Screen 1280×800, Mali-G52.

Camera2 device 0 is BACK, sensor orientation 180°, exposed by the external camera HAL. The device reports 640×480, 1280×720 and 1600×1200 among its YUV modes. No 1920×1080 sensor mode was advertised.

  • Rockchip (vendor) RKNPU driver reported 0.9.2. Vendor library /vendor/lib64/librknnrt.so identifies RKNN Runtime 1.5.2.
  • Vendor HIDL advertises rockchip.hardware.neuralnetworks@1.0. Android's public NNAPI NDK enumerated exactly one device, nnapi-reference, type CPU. The vendor RKNN HAL is not evidence of NNAPI NPU availability.
  • The APK runs CPU kernels and XNNPACK on ARM CPU. ORT profile with fixed 320 detector showed 57 XNNPACK and 23 CPU nodes. RKNN was inspected only.
  • No root, firmware changes or replacement of system libraries were used.

The dashboard shows temperature N/A when no public per-app CPU temperature signal is available. ADB can read the soc-thermal zone for bench sampling. The optional, read-only probe source is tools/nnapi-devices.c.

The camera is exclusive unless the OEM supports concurrent clients on that physical device. The two packages can be installed together.

The installed Android package requests CAMERA only. It acquired the camera, loaded both local sessions and ran inference with the package lacking INTERNET permission. ADB remained connected over Wi-Fi.

The stock FaceAPI baseline and Edge Vision remain installed under different packages. A separate split-screen smoke test confirmed Edge Vision camera and inference activity alongside the visible EVA x10 player. See the benchmark report for scope and measured rate.

The model-registry smoke test imported a pinned YuNet copy as a new version, validated it in ONNX Runtime, selected it, and ran live inference. The bundled fixed320 version was then selected and verified again on the live camera.