# stage_itscreen 1.0.13 — client 4.410.142
Release date: 2026-10-05.
- Publish the Modbus polling scheduler fix that keeps RS485 output commands responsive when configured slaves are offline.
- Limit each serial bus to one in-flight polling request while preserving per-range intervals, error backoff, telemetry and register statistics.
- Deliver client 4.410.142 through the existing Console updater without changing the stage installation contract.
Validation: native ARM64 Qt 5.15.2 compilation and two live MQTT-to-Modbus cycles on `g-box-c453df5f`. Register 1497 completed `0 → 1 → 0`; `itscreen-x11` remained active with zero restarts.
Binary SHA256: b996013b6b0182deb4b634acd69aadb1e69daaafe4a4a3f021da658cf8d4ff8f.

View File

@ -0,0 +1,6 @@
# stage_mqtt 1.0.1
- Replaces global bidirectional MQTT topic trees with a device-scoped allow-list.
- Separates outbound edge telemetry from inbound device commands.
- Preserves explicitly supported broadcast playback and event commands without reflecting them upstream.
- Prevents one edge from receiving and retransmitting telemetry belonging to other devices.

View File

@ -8,7 +8,7 @@
"version": "1.0.0" "version": "1.0.0"
}, },
"stage_mqtt": { "stage_mqtt": {
"version": "1.0.0" "version": "1.0.1"
}, },
"stage_z2m": { "stage_z2m": {
"version": "1.0.0" "version": "1.0.0"
@ -23,7 +23,7 @@
"version": "1.0.0" "version": "1.0.0"
}, },
"stage_itscreen": { "stage_itscreen": {
"version": "1.0.12" "version": "1.0.13"
}, },
"stage_reverse_tunnels": { "stage_reverse_tunnels": {
"version": "1.0.1" "version": "1.0.1"

Binary file not shown.

View File

@ -1 +1 @@
0613b944acda44b6e5b21bce68fbabe0fe7853ef486c73beb1801b9c1ab7fc98 itscreen b996013b6b0182deb4b634acd69aadb1e69daaafe4a4a3f021da658cf8d4ff8f itscreen

View File

@ -1 +1 @@
4.410.141 4.410.142

View File

@ -1,3 +1,3 @@
{ {
"version": "1.0.12" "version": "1.0.13"
} }

View File

@ -411,7 +411,7 @@ address ${REMOTE_HOST}:${REMOTE_PORT}
bridge_protocol_version mqttv311 bridge_protocol_version mqttv311
cleansession true cleansession true
# Use normal MQTT client bridge mode; private bridge mode can suppress OUT forwarding with bidirectional same-prefix mappings. # The allow-list below keeps inbound commands and outbound telemetry disjoint.
try_private false try_private false
notifications false notifications false
@ -428,29 +428,104 @@ bridge_tls_version tlsv1.2
__TLS__ __TLS__
fi fi
cat >>"$BRIDGE_CONF" <<'__MAP__' cat >>"$BRIDGE_CONF" <<__MAP__
# Topic mapping (IOMATEX v1 edge contract) # IOMATEX v1 edge contract: this edge publishes only its health and receives only its commands.
topic v1/edge/# out 0 "" "" topic ${BRIDGE_BASE_TOPIC}/health/${DEVICE_ID} out 0 "" ""
topic v1/edge/# in 0 "" "" topic ${BRIDGE_BASE_TOPIC}/command/${DEVICE_ID}/# in 0 "" ""
# Legacy iomatex contract: device telemetry OUT.
topic iomatex/+/client/pub/${DEVICE_ID} out 0 "" ""
topic iomatex/+/client/pub/action/${DEVICE_ID} out 0 "" ""
topic iomatex/+/client/pub/module/${DEVICE_ID}/scanning out 0 "" ""
topic iomatex/+/client/pub/camera/${DEVICE_ID}/scanning out 0 "" ""
topic iomatex/+/client/pub/response/event/push out 0 "" ""
topic iomatex/+/client/pub/interface/${DEVICE_ID}/# out 0 "" ""
topic iomatex/+/client/pub/interface/meta/${DEVICE_ID} out 0 "" ""
topic iomatex/+/client/pub/interface/values/${DEVICE_ID} out 0 "" ""
topic iomatex/+/client/pub/interface/calibration/${DEVICE_ID} out 0 "" ""
topic iomatex/+/client/pub/component/plays/${DEVICE_ID} out 0 "" ""
topic iomatex/+/client/pub/component/meta/${DEVICE_ID} out 0 "" ""
topic iomatex/+/client/pub/component/notify/${DEVICE_ID}/# out 0 "" ""
topic iomatex/+/\$devices/settings/${DEVICE_ID}/pub out 0 "" ""
topic iomatex/+/\$devices/alive/${DEVICE_ID} out 0 "" ""
topic iomatex/+/\$devices/error/${DEVICE_ID} out 0 "" ""
topic iomatex/+/\$devices/status/${DEVICE_ID} out 0 "" ""
topic iomatex/+/\$devices/properties/${DEVICE_ID}/pub out 0 "" ""
topic iomatex/\$devices/settings/${DEVICE_ID}/pub out 0 "" ""
topic iomatex/\$devices/alive/${DEVICE_ID} out 0 "" ""
topic iomatex/\$devices/error/${DEVICE_ID} out 0 "" ""
topic iomatex/\$devices/status/${DEVICE_ID} out 0 "" ""
topic iomatex/\$devices/properties/${DEVICE_ID}/pub out 0 "" ""
# Legacy iomatex contract: device commands IN.
topic iomatex/+/client/sub/config/${DEVICE_ID} in 0 "" ""
topic iomatex/+/client/sub/action/${DEVICE_ID} in 0 "" ""
topic iomatex/+/client/sub/module/${DEVICE_ID}/scanning in 0 "" ""
topic iomatex/+/client/sub/camera/${DEVICE_ID}/scanning in 0 "" ""
topic iomatex/+/client/sub/event/speech/widget/${DEVICE_ID} in 0 "" ""
topic iomatex/+/client/sub/interface/${DEVICE_ID} in 0 "" ""
topic iomatex/+/client/sub/interface/action/${DEVICE_ID} in 0 "" ""
topic iomatex/+/\$devices/settings/${DEVICE_ID}/sub in 0 "" ""
topic iomatex/+/\$devices/properties/${DEVICE_ID}/sub in 0 "" ""
topic iomatex/\$devices/settings/${DEVICE_ID}/sub in 0 "" ""
topic iomatex/\$devices/properties/${DEVICE_ID}/sub in 0 "" ""
# Intentional broadcast commands IN. No matching OUT wildcard is allowed.
topic iomatex/+/element/play in 0 "" ""
topic iomatex/+/client/sub/event/push/# in 0 "" ""
topic iomatex/+/client/sub/action/frames/# in 0 "" ""
topic iomatex/+/client/sub/action/playlist/# in 0 "" ""
__MAP__ __MAP__
if [[ "${LEGACY_ITSCREEN_TREE}" == "1" ]]; then if [[ "${LEGACY_ITSCREEN_TREE}" == "1" ]]; then
cat >>"$BRIDGE_CONF" <<'__LEGACY_ITSCREEN__' cat >>"$BRIDGE_CONF" <<__LEGACY_ITSCREEN__
# Legacy contract: full it-screen tree (bi-directional) # Legacy it-screen contract: device telemetry OUT.
topic it-screen/# out 0 "" "" topic it-screen/+/client/pub/${DEVICE_ID} out 0 "" ""
topic it-screen/# in 0 "" "" topic it-screen/+/client/pub/action/${DEVICE_ID} out 0 "" ""
topic it-screen/+/client/pub/module/${DEVICE_ID}/scanning out 0 "" ""
topic it-screen/+/client/pub/camera/${DEVICE_ID}/scanning out 0 "" ""
topic it-screen/+/client/pub/response/event/push out 0 "" ""
topic it-screen/+/client/pub/interface/${DEVICE_ID}/# out 0 "" ""
topic it-screen/+/client/pub/interface/meta/${DEVICE_ID} out 0 "" ""
topic it-screen/+/client/pub/interface/values/${DEVICE_ID} out 0 "" ""
topic it-screen/+/client/pub/interface/calibration/${DEVICE_ID} out 0 "" ""
topic it-screen/+/client/pub/component/plays/${DEVICE_ID} out 0 "" ""
topic it-screen/+/client/pub/component/meta/${DEVICE_ID} out 0 "" ""
topic it-screen/+/client/pub/component/notify/${DEVICE_ID}/# out 0 "" ""
topic it-screen/+/\$devices/settings/${DEVICE_ID}/pub out 0 "" ""
topic it-screen/+/\$devices/alive/${DEVICE_ID} out 0 "" ""
topic it-screen/+/\$devices/error/${DEVICE_ID} out 0 "" ""
topic it-screen/+/\$devices/status/${DEVICE_ID} out 0 "" ""
topic it-screen/+/\$devices/properties/${DEVICE_ID}/pub out 0 "" ""
topic it-screen/\$devices/settings/${DEVICE_ID}/pub out 0 "" ""
topic it-screen/\$devices/alive/${DEVICE_ID} out 0 "" ""
topic it-screen/\$devices/error/${DEVICE_ID} out 0 "" ""
topic it-screen/\$devices/status/${DEVICE_ID} out 0 "" ""
topic it-screen/\$devices/properties/${DEVICE_ID}/pub out 0 "" ""
# Legacy it-screen contract: device commands IN.
topic it-screen/+/client/sub/config/${DEVICE_ID} in 0 "" ""
topic it-screen/+/client/sub/action/${DEVICE_ID} in 0 "" ""
topic it-screen/+/client/sub/module/${DEVICE_ID}/scanning in 0 "" ""
topic it-screen/+/client/sub/camera/${DEVICE_ID}/scanning in 0 "" ""
topic it-screen/+/client/sub/event/speech/widget/${DEVICE_ID} in 0 "" ""
topic it-screen/+/client/sub/interface/${DEVICE_ID} in 0 "" ""
topic it-screen/+/client/sub/interface/action/${DEVICE_ID} in 0 "" ""
topic it-screen/+/\$devices/settings/${DEVICE_ID}/sub in 0 "" ""
topic it-screen/+/\$devices/properties/${DEVICE_ID}/sub in 0 "" ""
topic it-screen/\$devices/settings/${DEVICE_ID}/sub in 0 "" ""
topic it-screen/\$devices/properties/${DEVICE_ID}/sub in 0 "" ""
# Intentional broadcast commands IN. No matching OUT wildcard is allowed.
topic it-screen/+/element/play in 0 "" ""
topic it-screen/+/client/sub/event/push/# in 0 "" ""
topic it-screen/+/client/sub/action/frames/# in 0 "" ""
topic it-screen/+/client/sub/action/playlist/# in 0 "" ""
__LEGACY_ITSCREEN__ __LEGACY_ITSCREEN__
fi fi
cat >>"$BRIDGE_CONF" <<'__LEGACY_IOMATEX__'
# Legacy contract: full iomatex tree (bi-directional)
topic iomatex/# out 0 "" ""
topic iomatex/# in 0 "" ""
__LEGACY_IOMATEX__
chown root:mosquitto "$BRIDGE_CONF" || true chown root:mosquitto "$BRIDGE_CONF" || true
chmod 640 "$BRIDGE_CONF" || true chmod 640 "$BRIDGE_CONF" || true
} }
@ -493,14 +568,14 @@ report(){
echo "Base topic : ${BRIDGE_BASE_TOPIC:-v1/edge}" echo "Base topic : ${BRIDGE_BASE_TOPIC:-v1/edge}"
echo echo
echo "Bridge policy:" echo "Bridge policy:"
echo " OUT: v1/edge/#" echo " OUT: ${BRIDGE_BASE_TOPIC}/health/${DEVICE_ID}"
echo " IN : v1/edge/#" echo " IN : ${BRIDGE_BASE_TOPIC}/command/${DEVICE_ID}/#"
if [[ "${LEGACY_ITSCREEN_TREE:-0}" == "1" ]]; then if [[ "${LEGACY_ITSCREEN_TREE:-0}" == "1" ]]; then
echo " OUT: it-screen/#" echo " OUT: it-screen/<namespace>/client/pub/.../${DEVICE_ID}"
echo " IN : it-screen/#" echo " IN : it-screen/<namespace>/client/sub/.../${DEVICE_ID}"
fi fi
echo " OUT: iomatex/#" echo " OUT: iomatex/<namespace>/client/pub/.../${DEVICE_ID}"
echo " IN : iomatex/#" echo " IN : iomatex/<namespace>/client/sub/.../${DEVICE_ID}"
echo echo
} }

View File

@ -0,0 +1,56 @@
import pathlib
import unittest
INSTALLER = pathlib.Path(__file__).with_name("stage_mqtt_install.sh")
class MqttBridgeContractTest(unittest.TestCase):
@classmethod
def setUpClass(cls):
cls.source = INSTALLER.read_text(encoding="utf-8")
def test_global_bidirectional_trees_are_forbidden(self):
for topic in ("v1/edge/#", "iomatex/#", "it-screen/#"):
self.assertNotIn(f'topic {topic} out', self.source)
self.assertNotIn(f'topic {topic} in', self.source)
def test_health_and_commands_are_device_scoped(self):
self.assertIn(
"topic ${BRIDGE_BASE_TOPIC}/health/${DEVICE_ID} out",
self.source,
)
self.assertIn(
"topic ${BRIDGE_BASE_TOPIC}/command/${DEVICE_ID}/# in",
self.source,
)
def test_legacy_telemetry_and_commands_are_directional(self):
for prefix in ("iomatex", "it-screen"):
self.assertIn(
f"topic {prefix}/+/client/pub/interface/values/${{DEVICE_ID}} out",
self.source,
)
self.assertIn(
f"topic {prefix}/+/client/sub/interface/${{DEVICE_ID}} in",
self.source,
)
self.assertNotIn(
f"topic {prefix}/+/client/pub/# in",
self.source,
)
def test_broadcast_commands_never_have_outbound_wildcard(self):
for prefix in ("iomatex", "it-screen"):
self.assertIn(
f"topic {prefix}/+/client/sub/action/playlist/# in",
self.source,
)
self.assertNotIn(
f"topic {prefix}/+/client/sub/# out",
self.source,
)
if __name__ == "__main__":
unittest.main()

View File

@ -1,3 +1,3 @@
{ {
"version": "1.0.0" "version": "1.0.1"
} }

View File

@ -489,7 +489,7 @@ def mosquitto_card(ctx):
warnings, warnings,
details=[ details=[
{"label": "Local broker address", "value": "127.0.0.1:1883"}, {"label": "Local broker address", "value": "127.0.0.1:1883"},
{"label": "Bridged topic trees", "value": "v1/edge/# · it-screen/# · iomatex/#"}, {"label": "Bridge policy", "value": "Device-scoped telemetry OUT · commands IN"},
], ],
) )