From c705b7d62d5af8e23c991899df5ccb40b1a07133 Mon Sep 17 00:00:00 2001 From: Andrei Smaliak Date: Fri, 18 Sep 2026 13:36:47 +0200 Subject: [PATCH] Release Console 3.1.2 with N4D8C12 input/output mode control --- docs/releases/console-3.1.2.md | 11 ++ stage-releases.json | 2 +- stage_ui/console_core/ARCHITECTURE.md | 25 +++ stage_ui/console_core/backend/app.py | 23 ++- .../console_core/backend/modbus_backend.py | 161 +++++++++++++++--- .../backend/test_modbus_io_api.py | 42 +++++ .../backend/test_modbus_io_browser.cjs | 76 +++++++++ .../backend/test_modbus_io_relationship.py | 124 ++++++++++++++ .../console_core/frontend/console.i18n.js | 54 ++++++ stage_ui/console_core/frontend/console.js | 114 ++++++++++++- stage_ui/console_core/frontend/index.html | 6 +- .../console_core/modbus_profiles/n4d8c12.json | 56 ++++++ stage_ui/version.json | 2 +- 13 files changed, 663 insertions(+), 33 deletions(-) create mode 100644 docs/releases/console-3.1.2.md create mode 100644 stage_ui/console_core/backend/test_modbus_io_api.py create mode 100644 stage_ui/console_core/backend/test_modbus_io_browser.cjs create mode 100644 stage_ui/console_core/backend/test_modbus_io_relationship.py create mode 100644 stage_ui/console_core/modbus_profiles/n4d8c12.json diff --git a/docs/releases/console-3.1.2.md b/docs/releases/console-3.1.2.md new file mode 100644 index 0000000..5b34341 --- /dev/null +++ b/docs/releases/console-3.1.2.md @@ -0,0 +1,11 @@ +# Edge Console 3.1.2 — 2026-09-18 + +- Added the five input/output relationship modes for N4D8C12 / IOMATEX ExBd-12/12-12 to Modbus → Configuration Write, with descriptions, actual readback, explicit whole-board scope and independent desired/actual values. +- Added a separate N4D8C12 library profile with zero-based register 0x00FD; numeric responses are not treated as proof of board identity. ExBd Nano remains a separate profile. +- Added an authenticated maintenance operation that pauses the running client, checks the previous value, writes and verifies the requested value, releases the port and restores the client even after operation errors. Manual Modbus sessions must first be released. +- Reused the existing confirmation dialog, styling, localization and update delivery. Added Russian and Polish labels; other locales use the existing English fallback for new strings. +- Hardware and API tests cover invalid family/value, missing confirmation, stale state, busy port, read/write/readback failures and recovery failures. Browser checks cover 360/768/1024/1440 widths, cancel, read, write, target freezing and failed verification. + +Install through Health → Edge Console → Update 3.1.2. This updates stage_ui; +it does not change the IT-Screen App binary or stage_itscreen revision. No +installation on the user's live device is performed as part of publication. diff --git a/stage-releases.json b/stage-releases.json index 81da3e6..1d37dab 100644 --- a/stage-releases.json +++ b/stage-releases.json @@ -14,7 +14,7 @@ "version": "1.0.0" }, "stage_ui": { - "version": "3.1.1" + "version": "3.1.2" }, "stage_avahi": { "version": "1.0.0" diff --git a/stage_ui/console_core/ARCHITECTURE.md b/stage_ui/console_core/ARCHITECTURE.md index 2be3798..d50321a 100644 --- a/stage_ui/console_core/ARCHITECTURE.md +++ b/stage_ui/console_core/ARCHITECTURE.md @@ -40,3 +40,28 @@ Checks run in the background against our Git API. Mutations use authenticated JSON, explicit confirmation, an allowlisted stage and a pinned commit. The worker runs outside the Console service, with the same installer lock as CLI entrypoints. See [stage update contract](../../offline/STAGE_UPDATES.md) for publishing and API details. + +## Modbus input/output relationship (Console 3.1.2) + +The existing Modbus Configuration Write card owns the profile-gated selector. +`modbus_profiles/n4d8c12.json` defines the N4D8C12 / ExBd-12/12-12 profile +with zero-based holding register 253. It must not be substituted with ExBd Nano, +whose register addressing and capabilities differ. A numeric mode response is +not an identity signature: discovery reports an unknown device and the operator +must select the matching library profile and confirm the physical model. + +Authenticated JSON `POST /api/modbus/io-relationship` delegates to +`modbus_backend.io_relationship`. Missing `mode` reads; integer `mode` 0..4 +writes with required `expected` previous value. Both require `confirmed: true` +because a running client must be paused. This is a whole-board setting. + +The server owns acquire, read-before, optional write, readback and release with +restoration of the previously running service. It continues if the browser +closes, but this synchronous operation is not a reboot-persistent job. The shared +session guard excludes concurrent acquire/release; the transaction lock owner +rejects generic register operations. Existing manual sessions must be released +before this operation. Failed verification invalidates UI state; failed recovery +never reports success. The firmware's power-cycle persistence is not asserted. + +UI uses existing field/select/actionRow/card classes and the shared body-mounted +confirmation dialog. No new CSS or independent modal/serial transport is added. diff --git a/stage_ui/console_core/backend/app.py b/stage_ui/console_core/backend/app.py index 5b931b6..9ab8105 100644 --- a/stage_ui/console_core/backend/app.py +++ b/stage_ui/console_core/backend/app.py @@ -33,6 +33,7 @@ from modbus_backend import ( iomx04_set_relay as modbus_iomx04_set_relay, list_ports_payload as modbus_list_ports_payload, profiles_payload as modbus_profiles_payload, + io_relationship as modbus_io_relationship, read_audit as modbus_read_audit, read_device_config as modbus_read_device_config, read_registers as modbus_read_registers, @@ -53,7 +54,7 @@ APP_DIR = "/opt/iomatex-console" PUBLIC_DIR = os.path.join(APP_DIR, "public") PROVIDERS_DIR = os.path.join(APP_DIR, "providers.d") CONFIG_PATH = "/etc/iomatex/console.json" -UI_VERSION = "V 3.1.1" +UI_VERSION = "V 3.1.2" STORAGE_HEALTH_COMMAND = "/usr/local/sbin/iomatex-storage-health" ZONEINFO_ROOT = "/usr/share/zoneinfo" @@ -3668,6 +3669,26 @@ class Handler(BaseHTTPRequestHandler): except Exception as exc: self.send_json({"ok": False, "error": str(exc), "devices": [], "scan_log": []}, code=500) return + if parsed.path == "/api/modbus/io-relationship": + if self.headers.get("Content-Type", "").split(";", 1)[0].strip().lower() != "application/json": + self.send_json({"ok": False, "error": "JSON content type required"}, code=415) + return + payload = self.read_json_body() + if not isinstance(payload, dict): + self.send_json({"ok": False, "error": "Invalid JSON body"}, code=400) + return + try: + self.send_json(modbus_io_relationship( + port=str(payload.get("port", "")), family=str(payload.get("family", "")), + slave=int(payload.get("slave", 0)), baud=int(payload.get("baud", 0)), + parity=str(payload.get("parity", "none")), confirmed=payload.get("confirmed"), + mode=payload.get("mode"), expected=payload.get("expected"), + )) + except (ValueError, TypeError): + self.send_json({"ok": False, "error": "Invalid connection parameters"}, code=400) + except ModbusApiError as exc: + self.send_json({"ok": False, "error": exc.message}, code=exc.code) + return if parsed.path == "/api/modbus/read-config": payload = self.read_json_body() if payload is None: diff --git a/stage_ui/console_core/backend/modbus_backend.py b/stage_ui/console_core/backend/modbus_backend.py index 8498132..e1a8530 100644 --- a/stage_ui/console_core/backend/modbus_backend.py +++ b/stage_ui/console_core/backend/modbus_backend.py @@ -1,5 +1,6 @@ #!/usr/bin/env python3 import glob +from functools import wraps import json import os import re @@ -2337,6 +2338,7 @@ def validate_profile(data: Dict[str, Any], source_path: str) -> Dict[str, Any]: "registers": registers, "detection": normalize_detection_config(data, registers), "summary_registers": summary_registers, + "io_relationship": data.get("io_relationship") if family == "n4d8c12" else None, "comm_profiles": data.get("comm_profiles") or [], "capabilities": { "supports_id_write": bool((registers.get("slave_id") or {}).get("rw")), @@ -2372,6 +2374,7 @@ def profiles_payload() -> Dict[str, Any]: "display_name": item["display_name"], "transport": item["transport"], "comm_profiles": item.get("comm_profiles") or [], + "io_relationship": item.get("io_relationship"), "supports_serial_write": bool(item.get("capabilities", {}).get("supports_serial_write")), "supports_id_write": bool(item.get("capabilities", {}).get("supports_id_write")), } @@ -2447,6 +2450,8 @@ def ensure_port_locked(port: str) -> Dict[str, Any]: lock = read_lock(port) if not lock: raise ApiError("Acquire port before using Modbus operations", 409) + if lock.get("owner") == "io_relationship": + raise ApiError("An input/output mode operation owns this port", 409) return lock @@ -2463,7 +2468,23 @@ def ensure_port_available(port: str, allow_itscreen_conflict: bool = False) -> D return status -def acquire_session(port: str, stop_itscreen: bool, source: str = "ui") -> Dict[str, Any]: +_SESSION_OPERATION_LOCK = threading.RLock() + + +def session_operation(fn): + @wraps(fn) + def guarded(*args, **kwargs): + if not _SESSION_OPERATION_LOCK.acquire(blocking=False): + raise ApiError("A Modbus maintenance operation is running", 409) + try: + return fn(*args, **kwargs) + finally: + _SESSION_OPERATION_LOCK.release() + return guarded + + +@session_operation +def acquire_session(port: str, stop_itscreen: bool, source: str = "ui", owner: str = "modbus_tool") -> Dict[str, Any]: operations = [] status_before = port_status(port) if not status_before["exists"]: @@ -2473,29 +2494,31 @@ def acquire_session(port: str, stop_itscreen: bool, source: str = "ui") -> Dict[ itscreen_running = status_before["itscreen_running"] stopped_itscreen = False - if stop_itscreen and itscreen_running: - operations.append({"level": "info", "message": "Stopping it-screen service before Modbus session"}) - stop_result = stop_itscreen_service_wait() - if not stop_result.get("ok"): - raise ApiError(stop_result.get("error") or "Failed to stop it-screen service", 502) - stopped_itscreen = True - operations.append({"level": "success", "message": "it-screen service stopped; Modbus port is ready"}) - try: + if stop_itscreen and itscreen_running: + operations.append({"level": "info", "message": "Stopping it-screen service before Modbus session"}) + # Even a failed stop may have partially stopped the runtime. + stopped_itscreen = True + stop_result = stop_itscreen_service_wait() + if not stop_result.get("ok"): + raise ApiError(stop_result.get("error") or "Failed to stop it-screen service", 502) + operations.append({"level": "success", "message": "it-screen service stopped; Modbus port is ready"}) ensure_port_available(port, allow_itscreen_conflict=False) lock = acquire_lock(port, { - "owner": "modbus_tool", + "owner": owner, "source": source, "stop_itscreen": bool(stop_itscreen), "itscreen_was_running": bool(itscreen_running), "itscreen_stopped": bool(stopped_itscreen), }) - except Exception: + except Exception as exc: if stopped_itscreen and itscreen_running: try: - start_itscreen_service_wait() - except Exception: - pass + restored = start_itscreen_service_wait() + if not restored.get("ok"): + raise RuntimeError(restored.get("error") or "Service restart failed") + except Exception as recovery_error: + raise ApiError(f"{exc}; automation restoration failed: {recovery_error}", 502) from exc raise payload = { @@ -2507,22 +2530,33 @@ def acquire_session(port: str, stop_itscreen: bool, source: str = "ui") -> Dict[ "itscreen_stopped": stopped_itscreen, "operation_log": operations + [{"level": "success", "message": "Port acquired and locked for Modbus tool"}], } - append_audit({ - "action": "session_acquire", - "port": port, - "stop_itscreen": bool(stop_itscreen), - "itscreen_running": bool(itscreen_running), - "itscreen_stopped": bool(stopped_itscreen), - "success": True, - "source": source, - }) + try: + append_audit({ + "action": "session_acquire", + "port": port, + "stop_itscreen": bool(stop_itscreen), + "itscreen_running": bool(itscreen_running), + "itscreen_stopped": bool(stopped_itscreen), + "success": True, + "source": source, + }) + except Exception as exc: + release_lock(port) + if stopped_itscreen: + restored = start_itscreen_service_wait() + if not restored.get("ok"): + raise ApiError("Audit failed; automation restoration failed", 502) from exc + raise ApiError("Unable to record Modbus session audit", 500) from exc return payload -def release_session(port: str, restart_itscreen: bool, source: str = "ui") -> Dict[str, Any]: +@session_operation +def release_session(port: str, restart_itscreen: bool, source: str = "ui", owner: str = "modbus_tool") -> Dict[str, Any]: lock = read_lock(port) if not lock: raise ApiError("Port is not locked by modbus tool", 409) + if lock.get("owner") == "io_relationship" and owner != "io_relationship": + raise ApiError("An input/output mode operation owns this port", 409) operations = [{"level": "info", "message": "Releasing Modbus port lock"}] released = release_lock(port) restarted = False @@ -4461,3 +4495,82 @@ def iomx04_apply_timed_relay( "debug": result, "operation_log": [{"level": "success", "message": f"Relay {int(relay)} timed ON started"}], } + + +# The complete maintenance transaction stays on the server if the browser closes. +_IO_RELATIONSHIP_LOCK = threading.Lock() + + +@session_operation +def io_relationship(*, port: str, family: str, slave: int, baud: int, + parity: str, confirmed: bool, mode=None, expected=None, + source: str = "console_ui") -> Dict[str, Any]: + profile = get_profile(family) + spec = profile.get("io_relationship") + if not spec or family != "n4d8c12": + raise ApiError("Input/output mode is not supported for this family", 400) + if confirmed is not True: + raise ApiError("Confirm the board model and temporary automation pause", 409) + if (port not in list_uart_ports() or not 1 <= slave <= 63 + or baud not in profile["transport"]["scan_baud"] or parity != "none"): + raise ApiError("Invalid N4D8C12 connection", 400) + if mode is not None and (type(mode) is not int or mode not in range(5) + or type(expected) is not int or expected not in range(5)): + raise ApiError("Mode and previous mode must be integers from 0 to 4", 400) + if not _IO_RELATIONSHIP_LOCK.acquire(blocking=False): + raise ApiError("Another input/output mode operation is running", 409) + acquired = False + result = {"ok": False, "phase": "acquire", "port": port, "family": family, + "slave": slave, "requested_mode": mode, "write_attempted": False} + connection = dict(port=port, slave=slave, baud=baud, parity=parity, + address=int(spec["address"]), zero_based=True) + + def read_mode(): + data = mbpoll_read(**connection, count=1, register_type="holding", + decode_mode="uint16", retries=0) + if not data.get("ok") or not data.get("values"): + raise ApiError("Unable to read input/output mode", 502) + value = data["values"][0].get("value") + if type(value) is not int or value not in range(5): + raise ApiError("Unsupported input/output mode returned by board", 502) + return value + + try: + acquire_session(port, True, source=source, owner="io_relationship") + acquired = True + result["phase"] = "read" + previous = read_mode() + result["previous_mode"] = previous + if mode is not None: + if previous != expected: + raise ApiError("Mode changed since reading; read the board again", 409) + if mode != previous: + result["phase"] = "write" + result["write_attempted"] = True + written = mbpoll_write_register(**connection, value=mode) + if not written.get("ok"): + raise ApiError("Mode write failed; board state must be read again", 502) + result["phase"] = "verify" + actual = read_mode() + if actual != mode: + raise ApiError("Mode verification failed; board state must be read again", 502) + else: + actual = previous + result.update(ok=True, mode=actual, read_at=utc_now_iso(), phase="complete") + except Exception as exc: + result.update(ok=False, error=str(exc)) + finally: + try: + if acquired: + restored = release_session(port, True, source=source, owner="io_relationship") + result["restoration"] = {"ok": True, "restarted": restored["itscreen_restarted"]} + except Exception as exc: + result.update(ok=False, restoration={"ok": False, "error": str(exc)}) + result["error"] = (result.get("error", "") + "; Automation restoration failed: " + str(exc)).lstrip("; ") + finally: + _IO_RELATIONSHIP_LOCK.release() + try: + append_audit(dict(result, action="io_relationship", source=source, success=result["ok"])) + except Exception as exc: + result.update(ok=False, error="Unable to record mode audit: " + str(exc)) + return result diff --git a/stage_ui/console_core/backend/test_modbus_io_api.py b/stage_ui/console_core/backend/test_modbus_io_api.py new file mode 100644 index 0000000..56db77e --- /dev/null +++ b/stage_ui/console_core/backend/test_modbus_io_api.py @@ -0,0 +1,42 @@ +import http.client +import importlib.util +import json +from pathlib import Path +import threading +import unittest +from unittest import mock + +spec = importlib.util.spec_from_file_location('io_api_app', Path(__file__).with_name('app.py')) +app = importlib.util.module_from_spec(spec) +spec.loader.exec_module(app) + +class IoApiTest(unittest.TestCase): + def setUp(self): + self.server = app.ThreadingHTTPServer(('127.0.0.1',0), app.Handler) + threading.Thread(target=self.server.serve_forever,daemon=True).start() + self.addCleanup(self.server.server_close) + self.addCleanup(self.server.shutdown) + p=mock.patch.object(app.Handler,'log_message');p.start();self.addCleanup(p.stop) + + def post(self, data, content_type='application/json'): + c=http.client.HTTPConnection(*self.server.server_address) + c.request('POST','/api/modbus/io-relationship',json.dumps(data),{'Content-Type':content_type}) + r=c.getresponse();body=json.loads(r.read());c.close();return r.status,body + + def test_authentication_required(self): + with mock.patch.object(app.Handler,'auth_session',return_value=None), mock.patch.object(app,'modbus_io_relationship') as fn: + self.assertEqual(401,self.post({'confirmed':True})[0]);fn.assert_not_called() + + def test_body_validation_before_hardware(self): + with mock.patch.object(app.Handler,'auth_session',return_value={'username':'iomatex'}),mock.patch.object(app,'modbus_io_relationship') as fn: + self.assertEqual(415,self.post({},'text/plain')[0]) + self.assertEqual(400,self.post([])[0]) + self.assertEqual(400,self.post({'slave':'not-a-number'})[0]) + fn.assert_not_called() + + def test_authenticated_request_uses_shared_owner(self): + with mock.patch.object(app.Handler,'auth_session',return_value={'username':'iomatex'}),mock.patch.object(app,'modbus_io_relationship',return_value={'ok':True,'mode':0}) as fn: + args=dict(port='/dev/ttyS3',family='n4d8c12',slave=1,baud=9600,parity='none',mode=0,expected=1,confirmed=True) + self.assertEqual((200,{'ok':True,'mode':0}),self.post(args));fn.assert_called_once_with(**args) + +if __name__=='__main__':unittest.main() diff --git a/stage_ui/console_core/backend/test_modbus_io_browser.cjs b/stage_ui/console_core/backend/test_modbus_io_browser.cjs new file mode 100644 index 0000000..1c97f0f --- /dev/null +++ b/stage_ui/console_core/backend/test_modbus_io_browser.cjs @@ -0,0 +1,76 @@ +const {chromium}=require('playwright'); +const fs=require('node:fs'); +const assert=require('node:assert/strict'); +const path=require('node:path'); +const root=path.resolve(__dirname,'../frontend'); +(async()=>{ + const browser=await chromium.launch({headless:true}); + try { + const page=await browser.newPage(); const errors=[]; const calls=[]; let mode=1; let fail=false; + page.on('pageerror',e=>errors.push(e.message)); + const profile={family:'n4d8c12',display_name:'IOMATEX ExBd-12/12-12 (N4D8C12)',transport:{default_baud:9600,default_parity:'none'},io_relationship:{address:253,channel_count:12}}; + await page.route('http://edge.test/**',async route=>{ + const p=new URL(route.request().url()).pathname; + if(p.startsWith('/api/')){ + let data={ok:true}; + if(p==='/api/auth/session')data={ok:true,authenticated:true,username:'iomatex',expires_at:Date.now()/1000+3600}; + if(p==='/api/modbus/ports')data={ok:true,ports:[{port:'/dev/ttyS3',locked:false,itscreen_running:true}]}; + if(p==='/api/modbus/profiles')data={ok:true,profiles:[profile]}; + if(p==='/api/modbus/io-relationship'){ + const body=route.request().postDataJSON();calls.push(body); + if(fail)data={ok:false,error:'Mode verification failed; board state must be read again'}; + else {if(body.mode!==undefined)mode=body.mode;data={ok:true,mode,read_at:new Date().toISOString(),restoration:{ok:true,restarted:true}};} + } + return route.fulfill({contentType:'application/json',body:JSON.stringify(data)}); + } + const file=p==='/'?'index.html':p.slice(1); + if(!['index.html','console.js','console.i18n.js','console.css'].includes(file))return route.fulfill({status:404,body:''}); + let body=fs.readFileSync(root+'/'+file,'utf8'); + if(file==='console.js')body=body.replace(' function modbusState() {',` window.__ioFixture = function () { + state.modbus.selectedDevice={port:'/dev/ttyS3',slave:1,baud:9600,parity:'none',familyDetection:{state:'unknown'}}; + state.modbus.readConfigStatus='success'; + state.modbus.port='/dev/ttyS3'; + renderActiveTab(); + }; + function modbusState() {`); + return route.fulfill({contentType:file.endsWith('js')?'text/javascript':file.endsWith('css')?'text/css':'text/html',body}); + }); + await page.addInitScript(()=>localStorage.setItem('consoleLanguage','ru')); + await page.goto('http://edge.test/'); + await page.locator('#tabModbus').click(); + await page.waitForFunction(()=>typeof window.__ioFixture==='function'); + await page.evaluate(()=>window.__ioFixture()); + await page.locator('select[onchange="window.__modbusSelectLibraryFamily(this.value)"]').selectOption('n4d8c12'); + const apply=page.getByRole('button',{name:'Применить режим',exact:true}); + await page.locator('#modbusIoMode').waitFor(); + assert.equal(await apply.isDisabled(),true,'cannot apply unread mode'); + for(const width of [360,768,1024,1440]){ + await page.setViewportSize({width,height:900}); + assert.equal(await page.evaluate(()=>document.documentElement.scrollWidth>innerWidth+1),false,'overflow '+width); + } + await page.getByRole('button',{name:'Прочитать с платы',exact:true}).click(); + await page.getByRole('dialog').waitFor(); + assert.equal(await page.locator('.modalBackdrop').evaluate(el=>el.parentNode===document.body),true); + await page.keyboard.press('Escape');assert.equal(calls.length,0); + await page.getByRole('button',{name:'Прочитать с платы',exact:true}).click(); + await page.getByRole('dialog').getByRole('button',{name:'Продолжить',exact:true}).click(); + await page.waitForFunction(()=>document.querySelector('#modbusIoMode').value==='1'); + assert.equal(calls.length,1);assert.equal(calls[0].mode,undefined); + await page.locator('#modbusIoMode').selectOption('0'); + await apply.click(); + await page.getByRole('dialog').waitFor(); + assert.match(await page.getByRole('dialog').innerText(),/Переключение с фиксацией → Независимые/); + // Target is frozen while confirmation is open. + await page.evaluate(()=>window.__modbusSetPort('/dev/ttyS4')); + await page.getByRole('dialog').getByRole('button',{name:'Продолжить',exact:true}).click(); + await page.waitForFunction(()=>document.querySelector('#modbusIoMode').value==='0'); + assert.equal(calls[1].mode,0);assert.equal(calls[1].expected,1);assert.equal(calls[1].port,'/dev/ttyS3'); + assert.equal(await apply.isDisabled(),true); + fail=true;await page.locator('#modbusIoMode').selectOption('2');await apply.click(); + await page.getByRole('dialog').getByRole('button',{name:'Продолжить',exact:true}).click(); + await page.getByText('Проверка режима не пройдена. Прочитайте состояние платы заново.',{exact:true}).first().waitFor(); + assert.equal(await apply.isDisabled(),true,'failed verification invalidates cached mode'); + assert.deepEqual(errors,[]); + console.log('Modbus UI: 4 viewports, manual profile, unread/cancel/read/write/stale state, frozen target, failure passed'); + } finally {await browser.close();} +})().catch(e=>{console.error(e);process.exit(1)}); diff --git a/stage_ui/console_core/backend/test_modbus_io_relationship.py b/stage_ui/console_core/backend/test_modbus_io_relationship.py new file mode 100644 index 0000000..065a6e6 --- /dev/null +++ b/stage_ui/console_core/backend/test_modbus_io_relationship.py @@ -0,0 +1,124 @@ +import contextlib +import json +from pathlib import Path +import unittest +from unittest import mock +import modbus_backend as mb + + +class IoRelationshipTest(unittest.TestCase): + def setUp(self): + self.stack = contextlib.ExitStack() + self.addCleanup(self.stack.close) + self.stack.enter_context(mock.patch.object(mb, 'MODBUS_PROFILES_DIR', str(Path(__file__).resolve().parent.parent / 'modbus_profiles'))) + self.stack.enter_context(mock.patch.object(mb, 'list_uart_ports', return_value=['/dev/ttyS3'])) + self.acquire = self.stack.enter_context(mock.patch.object(mb, 'acquire_session')) + self.release = self.stack.enter_context(mock.patch.object(mb, 'release_session', return_value={'itscreen_restarted': True})) + self.read = self.stack.enter_context(mock.patch.object(mb, 'mbpoll_read')) + self.write = self.stack.enter_context(mock.patch.object(mb, 'mbpoll_write_register', return_value={'ok': True})) + self.audit = self.stack.enter_context(mock.patch.object(mb, 'append_audit')) + self.args = dict(port='/dev/ttyS3', family='n4d8c12', slave=1, baud=9600, parity='none', confirmed=True) + + def values(self, *values): + self.read.side_effect = [{'ok': True, 'values': [{'value': value}]} for value in values] + + def test_read_only_stops_and_restores_without_writing(self): + self.values(1) + result = mb.io_relationship(**self.args) + self.assertTrue(result['ok']) + self.assertEqual(1, result['mode']) + self.write.assert_not_called() + self.release.assert_called_once_with('/dev/ttyS3', True, source='console_ui', owner='io_relationship') + self.assertEqual(253, self.read.call_args.kwargs['address']) + self.assertTrue(self.read.call_args.kwargs['zero_based']) + + def test_write_all_five_modes_with_readback(self): + for mode in range(5): + with self.subTest(mode=mode): + old = (mode + 1) % 5 + self.values(old, mode) + result = mb.io_relationship(**self.args, mode=mode, expected=old) + self.assertTrue(result['ok']) + self.assertEqual(mode, result['mode']) + self.assertEqual(mode, self.write.call_args.kwargs['value']) + + def test_stale_read_never_writes_and_restores(self): + self.values(2) + result = mb.io_relationship(**self.args, mode=0, expected=1) + self.assertFalse(result['ok']) + self.write.assert_not_called() + self.release.assert_called_once() + + def test_failure_restores_in_read_write_and_verify(self): + for phase in ['read', 'write', 'verify']: + with self.subTest(phase=phase): + self.release.reset_mock() + self.values(1, 2 if phase == 'verify' else 0) + if phase == 'read': self.read.side_effect = RuntimeError('read failed') + self.write.return_value = {'ok': phase != 'write'} + result = mb.io_relationship(**self.args, mode=0, expected=1) + self.assertFalse(result['ok']) + self.assertEqual(phase, result['phase']) + self.release.assert_called_once() + + def test_restart_failure_never_claims_success(self): + self.values(1, 0) + self.release.side_effect = RuntimeError('restart failed') + result = mb.io_relationship(**self.args, mode=0, expected=1) + self.assertFalse(result['ok']) + self.assertEqual(0, result['mode']) + self.assertFalse(result['restoration']['ok']) + + def test_busy_session_not_released(self): + self.acquire.side_effect = mb.ApiError('busy', 409) + result = mb.io_relationship(**self.args) + self.assertFalse(result['ok']) + self.read.assert_not_called() + self.release.assert_not_called() + + def test_invalid_or_unconfirmed_request_never_touches_service(self): + for changes in [dict(family='exbd_nano'), dict(confirmed=False), dict(mode=5, expected=1), dict(mode=True, expected=1), dict(mode=0, expected=None), dict(slave=0), dict(port='/tmp/not-a-port')]: + with self.subTest(changes=changes): + with self.assertRaises(mb.ApiError): mb.io_relationship(**dict(self.args, **changes)) + self.acquire.assert_not_called() + + def test_unknown_board_value_never_writes(self): + self.values(65535) + result = mb.io_relationship(**self.args, mode=0, expected=1) + self.assertFalse(result['ok']) + self.write.assert_not_called() + self.release.assert_called_once() + + def test_other_register_clients_cannot_use_transaction_lock(self): + with mock.patch.object(mb, 'read_lock', return_value={'owner': 'io_relationship'}): + with self.assertRaises(mb.ApiError): mb.ensure_port_locked('/dev/ttyS3') + + def test_profile_does_not_guess_identity_from_mode_number(self): + profile = mb.get_profile('n4d8c12') + self.assertFalse(profile['capabilities']['supports_id_write']) + self.assertFalse(profile['capabilities']['supports_serial_write']) + register = profile['detection']['family_register'] + result = mb.evaluate_family_detection(profile, {'ok':True, 'values':[{'value':1,'raw':'1'}]}, register) + self.assertNotEqual('recognized', result['state']) + +class SessionRecoveryTest(unittest.TestCase): + def test_failed_stop_still_restores_previously_running_service(self): + with mock.patch.object(mb, 'port_status', return_value={'exists':True,'locked':False,'itscreen_running':True}), \ + mock.patch.object(mb, 'stop_itscreen_service_wait', return_value={'ok':False,'error':'stop timeout'}), \ + mock.patch.object(mb, 'start_itscreen_service_wait', return_value={'ok':True}) as restart: + with self.assertRaises(mb.ApiError): mb.acquire_session('/dev/ttyS3',True) + restart.assert_called_once() + + def test_session_guard_excludes_other_threads(self): + import threading + blocked=[] + def other_client(): + try: mb.release_session('/dev/ttyS3',True) + except mb.ApiError as exc: blocked.append(exc.code) + with mb._SESSION_OPERATION_LOCK: + thread=threading.Thread(target=other_client) + thread.start();thread.join(timeout=2) + self.assertFalse(thread.is_alive()) + self.assertEqual([409],blocked) + +if __name__ == '__main__': unittest.main() diff --git a/stage_ui/console_core/frontend/console.i18n.js b/stage_ui/console_core/frontend/console.i18n.js index 1cfd21c..b8c0407 100644 --- a/stage_ui/console_core/frontend/console.i18n.js +++ b/stage_ui/console_core/frontend/console.i18n.js @@ -12,6 +12,33 @@ ], translations: { ru: { + "Input/output relationship": "Связь входов и реле", + "Independent inputs and outputs": "Независимые входы и выходы", + "Toggle with memory": "Переключение с фиксацией", + "Interlocking": "Взаимная блокировка", + "Momentary pulse": "Импульсный режим", + "Pair interlocking": "Блокировка парами", + "Inputs report sensor states. Models control relays without direct input coupling.": "Датчики передают состояния. Реле управляются моделями, без прямой связи с входами.", + "Each input activation toggles its corresponding relay.": "Каждое срабатывание входа переключает соответствующее реле.", + "Activating a channel excludes the other channels.": "Включение канала блокирует включение остальных.", + "An input activation produces a brief relay pulse (1 second in the manual).": "Срабатывание входа даёт короткий импульс реле (1 секунда по руководству).", + "Relays exclude each other within pairs 1–2, 3–4, …, 11–12.": "Реле блокируют друг друга в парах 1–2, 3–4, …, 11–12.", + "Read from board": "Прочитать с платы", + "Not read": "Не считано", + "Operating mode": "Режим работы", + "Read the mode first": "Сначала прочитайте режим", + "Applies to all 12 channels of this board.": "Применяется ко всем 12 каналам платы.", + "Release the current Modbus session first. This operation manages its own pause and recovery.": "Сначала освободите порт текущего сеанса Modbus. Эта операция сама приостановит и восстановит управление.", + "Apply mode": "Применить режим", + "Confirm that the selected board is N4D8C12 / ExBd-12/12-12. Automation will pause temporarily and then resume. The mode applies to all 12 channels.": "Подтвердите, что выбрана плата N4D8C12 / ExBd-12/12-12. Автоматика временно остановится и затем возобновится. Режим действует на все 12 каналов.", + "Mode verified; automation restored": "Режим проверен, управление восстановлено", + "Mode read; automation restored": "Режим считан, управление восстановлено", + "Mode operation failed": "Операция с режимом не выполнена", + "Mode changed since reading; read the board again": "Режим изменился после чтения. Прочитайте плату заново.", + "Unable to read input/output mode": "Не удалось прочитать режим связи входов и реле", + "Unsupported input/output mode returned by board": "Плата вернула неподдерживаемый режим", + "Mode write failed; board state must be read again": "Запись не подтверждена. Прочитайте состояние платы заново.", + "Mode verification failed; board state must be read again": "Проверка режима не пройдена. Прочитайте состояние платы заново.", "Another installation is running": "Уже выполняется другая установка", "Check available versions before installing.": "Перед установкой проверьте доступные версии.", "The stage release catalog has not been published to Git yet.": "Каталог версий стадий ещё не опубликован в Git.", @@ -540,6 +567,33 @@ "unknown": "неизвестно" }, pl: { + "Input/output relationship": "Powiązanie wejść i przekaźników", + "Independent inputs and outputs": "Niezależne wejścia i wyjścia", + "Toggle with memory": "Przełączanie z pamięcią", + "Interlocking": "Blokada wzajemna", + "Momentary pulse": "Tryb impulsowy", + "Pair interlocking": "Blokada parami", + "Inputs report sensor states. Models control relays without direct input coupling.": "Wejścia zgłaszają stan czujników. Modele sterują przekaźnikami bez bezpośredniego powiązania z wejściami.", + "Each input activation toggles its corresponding relay.": "Każde zadziałanie wejścia przełącza odpowiedni przekaźnik.", + "Activating a channel excludes the other channels.": "Włączenie kanału wyklucza włączenie pozostałych.", + "An input activation produces a brief relay pulse (1 second in the manual).": "Zadziałanie wejścia wyzwala krótki impuls przekaźnika (1 sekunda według instrukcji).", + "Relays exclude each other within pairs 1–2, 3–4, …, 11–12.": "Przekaźniki blokują się wzajemnie w parach 1–2, 3–4, …, 11–12.", + "Read from board": "Odczytaj z modułu", + "Not read": "Nie odczytano", + "Operating mode": "Tryb pracy", + "Read the mode first": "Najpierw odczytaj tryb", + "Applies to all 12 channels of this board.": "Dotyczy wszystkich 12 kanałów modułu.", + "Release the current Modbus session first. This operation manages its own pause and recovery.": "Najpierw zwolnij port bieżącej sesji Modbus. Ta operacja sama wstrzyma i przywróci sterowanie.", + "Apply mode": "Zastosuj tryb", + "Confirm that the selected board is N4D8C12 / ExBd-12/12-12. Automation will pause temporarily and then resume. The mode applies to all 12 channels.": "Potwierdź wybór modułu N4D8C12 / ExBd-12/12-12. Automatyka zostanie chwilowo wstrzymana, a następnie wznowiona. Tryb dotyczy wszystkich 12 kanałów.", + "Mode verified; automation restored": "Tryb zweryfikowany, sterowanie przywrócone", + "Mode read; automation restored": "Tryb odczytany, sterowanie przywrócone", + "Mode operation failed": "Operacja zmiany trybu nie powiodła się", + "Mode changed since reading; read the board again": "Tryb zmienił się od odczytu. Odczytaj moduł ponownie.", + "Unable to read input/output mode": "Nie można odczytać trybu powiązania wejść i przekaźników", + "Unsupported input/output mode returned by board": "Moduł zwrócił nieobsługiwany tryb", + "Mode write failed; board state must be read again": "Zapis nie został potwierdzony. Odczytaj stan modułu ponownie.", + "Mode verification failed; board state must be read again": "Weryfikacja trybu nie powiodła się. Odczytaj stan modułu ponownie.", "Open menu": "Otwórz menu", "Close menu": "Zamknij menu", "Language": "Język", diff --git a/stage_ui/console_core/frontend/console.js b/stage_ui/console_core/frontend/console.js index 35d1b86..c046564 100644 --- a/stage_ui/console_core/frontend/console.js +++ b/stage_ui/console_core/frontend/console.js @@ -48,7 +48,7 @@ { mode: "test_by", label: "test.it-screen.by", host: "rest.test.it-screen.by" }, { mode: "custom", label: "Custom", host: "" } ]; - const UI_VERSION = "V 3.1.1"; + const UI_VERSION = "V 3.1.2"; const ITSCREEN_LOG_INITIAL_LINES = 50; const ITSCREEN_LOG_BUFFER_LIMIT = 300; const ITSCREEN_LOG_BATCH_MS = 250; @@ -239,6 +239,7 @@ selectedDevice: null, currentConfig: null, lastWriteResult: null, + ioRelationship: { key: "", actual: null, selected: "", readAt: "", error: "" }, readConfigStatus: "idle", readConfigMessage: "", writeLog: [], @@ -4026,6 +4027,7 @@ const currentConfig = modbusState().currentConfig; if (!currentConfig) { const rows = [ + ...(modbusSelectedProfile()?.io_relationship ? [{ label: t("Input/output relationship"), value: modbusIoState().actual === null ? t("Not read") : t(IO_MODE_LABELS[modbusIoState().actual]) }] : []), { label: t("Port"), value: textValue(selectedDevice.port, "-") }, { label: t("Selected slave"), value: textValue(selectedDevice.slave, "-") }, { label: t("Baud"), value: textValue(selectedDevice.baud, "-") }, @@ -4049,6 +4051,7 @@ const firmwareVersion = modbusSummary(summary.firmwareVersion, {}); const serial = modbusSummary(summary.serial, {}); const rows = [ + ...(modbusSelectedProfile()?.io_relationship ? [{ label: t("Input/output relationship"), value: modbusIoState().actual === null ? t("Not read") : t(IO_MODE_LABELS[modbusIoState().actual]) }] : []), { label: t("Port"), value: textValue(currentConfig.port, textValue(selectedDevice.port, "-")) }, { label: t("Selected slave"), value: textValue(summary.slaveId, "-") }, { label: t("Baud"), value: textValue(summary.baudDisplay, t("Unknown")) }, @@ -4111,6 +4114,54 @@ `; } + const IO_MODE_LABELS = ["Independent inputs and outputs", "Toggle with memory", "Interlocking", "Momentary pulse", "Pair interlocking"]; + const IO_MODE_HINTS = [ + "Inputs report sensor states. Models control relays without direct input coupling.", + "Each input activation toggles its corresponding relay.", + "Activating a channel excludes the other channels.", + "An input activation produces a brief relay pulse (1 second in the manual).", + "Relays exclude each other within pairs 1–2, 3–4, …, 11–12." + ]; + + function modbusIoConnection() { + return { port: modbusState().port, family: modbusEditorFamily(), ...modbusCurrentConnection() }; + } + + function modbusIoState() { + const log = modbusState(); + const key = JSON.stringify(modbusIoConnection()); + if (log.ioRelationship.key !== key) { + log.ioRelationship = { key, actual: null, selected: "", readAt: "", error: "" }; + } + return log.ioRelationship; + } + + function renderModbusIoRelationship() { + const profile = modbusSelectedProfile(); + if (!profile || !profile.io_relationship || !modbusState().selectedDevice) return ""; + const io = modbusIoState(); + const busy = !!modbusState().busyAction; + const locked = !!(modbusSelectedPortStatus() || {}).locked; + return `
+
${esc(t("Input/output relationship"))}
+
${esc(t("Read from board"))}: ${esc(io.actual === null ? t("Not read") : t(IO_MODE_LABELS[io.actual]))}${io.readAt ? ` · ${esc(formatTimestamp(io.readAt))}` : ""}
+ +
${io.selected !== "" ? esc(t(IO_MODE_HINTS[Number(io.selected)])) : ""}
+
${esc(t("Applies to all 12 channels of this board."))}
+ ${locked ? `
${esc(t("Release the current Modbus session first. This operation manages its own pause and recovery."))}
` : ""} + ${io.error ? `` : ""} +
+ + +
+
`; + } + function renderModbusReadConfigState() { const log = modbusState(); if (log.readConfigStatus === "success" && log.readConfigMessage) { @@ -4355,10 +4406,11 @@
${renderPanelTitle(t("Configuration Write"), "modbus_configuration_write")}
${modbusWriteStatusMeta()} - ${writeAccess.enabled ? "" : ``} + ${writeAccess.enabled || (profile && profile.io_relationship) ? "" : ``} ${log.selectedDevice && !modbusConfigPanelReady() ? `
${esc(t("Read config to activate Configuration Write for the selected device."))}
` : ""} ${modbusRequiresLibrarySelection() ? renderModbusDeviceLibrarySelector() : ""} - ${modbusStandardEditorEnabled() ? ` + ${renderModbusIoRelationship()} + ${modbusStandardEditorEnabled() && !(profile && profile.io_relationship) ? ` ${modbusEm01FamilySelected() ? `
${esc(modbusEm01BaudComment())}
` : (!supportsSerialWrite ? `
${esc(t("Baud rate and parity write are not configured for this family yet. Slave ID write is available."))}
` : "") @@ -5685,7 +5737,56 @@ updateItscreenLogsUi(); }; + window.__modbusSetIoMode = function (value) { + if (modbusState().busyAction || !/^[0-4]$/.test(value)) return; + modbusIoState().selected = value; + if (state.activeTab === "modbus") renderActiveTab(); + }; + + window.__modbusIoRelationship = async function (write) { + const log = modbusState(); + const profile = modbusSelectedProfile(); + if (log.busyAction || !log.selectedDevice || !profile?.io_relationship) return; + const io = modbusIoState(); + if (write && (io.actual === null || !/^[0-4]$/.test(io.selected) || Number(io.selected) === io.actual)) return; + const connection = modbusIoConnection(); + const target = Number(io.selected); + log.busyAction = "io_relationship"; + try { + const message = `${profile.display_name} · ${connection.port} · ${t("Slave ID")}: ${connection.slave}\n\n` + + (write ? `${t(IO_MODE_LABELS[io.actual])} → ${t(IO_MODE_LABELS[target])}\n\n` : "") + + t("Confirm that the selected board is N4D8C12 / ExBd-12/12-12. Automation will pause temporarily and then resume. The mode applies to all 12 channels."); + if (!await confirmAction(t(write ? "Apply mode" : "Read from board"), message)) return; + if (JSON.stringify(modbusIoConnection()) !== io.key) return; + io.error = ""; + if (state.activeTab === "modbus") renderActiveTab(); + const payload = await fetchJsonAllowLogicalFailure("/api/modbus/io-relationship", { + method: "POST", headers: { "Content-Type": "application/json" }, + body: JSON.stringify({ ...connection, confirmed: true, ...(write ? { mode: target, expected: io.actual } : {}) }) + }); + if (!payload.ok) throw new Error(translateUiText(payload.error || "Mode operation failed")); + if (JSON.stringify(modbusIoConnection()) === io.key) { + io.actual = payload.mode; + io.selected = String(payload.mode); + io.readAt = payload.read_at; + } + appendModbusLog(`${t("Input/output relationship")}: ${t(IO_MODE_LABELS[payload.mode])}`, "success"); + showToast("success", t(write ? "Mode verified; automation restored" : "Mode read; automation restored")); + } catch (error) { + io.actual = null; + io.readAt = ""; + io.error = translateUiText(error.message || "Mode operation failed"); + appendModbusLog(io.error, "error"); + showToast("error", io.error); + } finally { + log.busyAction = ""; + try { await loadModbus({ force: true }); } catch (error) { showToast("error", error.message); } + if (state.activeTab === "modbus") renderActiveTab(); + } + }; + window.__modbusSetPort = function (value) { + if (modbusState().busyAction === "io_relationship") return; modbusState().port = value; if (state.activeTab === "modbus") renderActiveTab(); }; @@ -5770,6 +5871,7 @@ }; window.__modbusSelectDevice = function (index) { + if (modbusState().busyAction === "io_relationship") return; const log = modbusState(); const item = (log.discovery.devices || [])[index]; if (!item) return; @@ -5790,6 +5892,7 @@ }; window.__modbusSelectLibraryFamily = async function (value) { + if (modbusState().busyAction === "io_relationship") return; const log = modbusState(); log.manualFamily = value; log.family = value && value !== "__new__" ? value : ""; @@ -5799,6 +5902,11 @@ log.lastWriteResult = null; log.registerForm.lastResult = null; if (state.activeTab === "modbus") renderActiveTab(); + if (modbusSelectedProfile()?.io_relationship) { + log.readConfigStatus = "ready"; + if (state.activeTab === "modbus") renderActiveTab(); + return; + } if (value && value !== "__new__" && log.selectedDevice) { await executeModbusReadConfig({ familyOverride: value, autoSelected: true }); } diff --git a/stage_ui/console_core/frontend/index.html b/stage_ui/console_core/frontend/index.html index 60dbffc..c65924f 100644 --- a/stage_ui/console_core/frontend/index.html +++ b/stage_ui/console_core/frontend/index.html @@ -23,7 +23,7 @@ } catch (error) {} })(); - +
@@ -108,7 +108,7 @@
- - + + diff --git a/stage_ui/console_core/modbus_profiles/n4d8c12.json b/stage_ui/console_core/modbus_profiles/n4d8c12.json new file mode 100644 index 0000000..22344e8 --- /dev/null +++ b/stage_ui/console_core/modbus_profiles/n4d8c12.json @@ -0,0 +1,56 @@ +{ + "family": "n4d8c12", + "title": "IOMATEX ExBd-12/12-12 (N4D8C12)", + "display_name": "IOMATEX ExBd-12/12-12 (N4D8C12)", + "discovery_enabled": true, + "transport": { + "protocol": "modbus_rtu", + "default_baud": 9600, + "default_parity": "none", + "zero_based": true, + "scan_baud": [ + 1200, + 2400, + 4800, + 9600, + 19200 + ], + "scan_parity": [ + "none" + ] + }, + "detection": { + "family_register": { + "address": 253, + "count": 1, + "type": "holding" + }, + "match": [] + }, + "registers": { + "test_read": { + "address": 253, + "count": 1, + "type": "holding" + } + }, + "summary_registers": { + "relationship": { + "address": 253, + "count": 1, + "type": "holding", + "value_format": "enum", + "enum_map": { + "0": "Unrelated", + "1": "Self-locking", + "2": "Interlocking", + "3": "Momentary", + "4": "Two-channel interlocking" + } + } + }, + "io_relationship": { + "address": 253, + "channel_count": 12 + } +} diff --git a/stage_ui/version.json b/stage_ui/version.json index 50ff2d2..9a9f9b5 100644 --- a/stage_ui/version.json +++ b/stage_ui/version.json @@ -1,3 +1,3 @@ { - "version": "3.1.1" + "version": "3.1.2" }